Gima International Catalogue 2014-2015 - page 15

DIAGNOSTIC TESTS - LABORATORY
6
0344
23950
Wide LCD display
for easy reading
100% italian
technology
Multifunction
Each strip box has its own
coded chip for safe
measurement
CHOLESTEROL, TRIGLYCERIDES, GLUCOSE POCKETMONITORS
SELF TEST DEVICE
23955
23956
23957
23958
23959
23960
23961
23962
23963
GIMA
code
STRIPS AND CONTROL SOLUTION FOR MULTICARE
TECHNICAL SPECIFICATIONS
Measuring range glucose: 25-500mg/dl (1.3-28 mmol/l)
triglycerides 50-500 mg/dL (0.5-5.6 mmol/l)
cholesterol 130-400 mg/dL (3.3-10.2 mmol/l)
Memory: 255 test results with date and time
Size: 48x104x20.5 mm
Weight: 65 g
Batteries: 2 batteries
Glucose strips - tube of 25 strips + 1 chip
Glucose strips - tube of 50 strips + 1 chip
Cholesterol strips - tube of 5 strips + 1 chip
Cholesterol strips - tube of 25 strips + 1 chip
Triglycerides strips - tube of 5 strips + 1 chip
Triglycerides strips - tube of 25 strips + 1 chip
Glucose control solution
Cholesterol control solution
Triglycerides control solution
LANCETS FOR MULTICARE AND MULTICARE "IN"
CONTROL SOLUTION FOR MULTICARE "IN"
23969
23970
23971
23972
23973
23974
23978
23979
23980
23940
23916
Glucose strips biosensor - tube of 25 strips + 1 chip
Glucose strips biosensor - tube of 50 strips + 1 chip
Cholesterol strips - tube of 5 strips + 1 chip
Cholesterol strips - tube of 25 strips + 1 chip
Triglycerides strips - tube of 5 strips + 1 chip
Triglycerides strips - tube of 25 strips + 1 chip
Glucose control solution
Cholesterol control solution
Triglycerides control solution
Lancets 28G - sterile - bag of 25 pcs
Lancets 28G - sterile - box of 100
GIMA
code
SPARE STRIPS FOR MULTICARE "IN" - 7 LANGUAGE BOX
MULTICARE “IN” - SELF CONTROL OF RISK FACTOR
0344
23965
23965
Cholesterol
Triglicerides
Glucose
TECHNICAL SPECIFICATIONS
Measuring range Measuring time Blood sample
Glucose electro-chemical: 10-600mg/dl
5"
1 μl
Cholesterol
130-400 mg/dl
30"
10 μl
Triglycerides
50-500 mg dl
30"
10 μl
Memory:
500 test results with date and time
Batteries:
2 lithium batteries Cr 2032 3 Volts (32212)
Size:
97x49x20.5 mm
Weight:
65 g
3 IN 1: CHOLESTEROL,
TRIGLYCERIDES,
GLUCOSE BIOSENSOR
BIOSENSOR SUCTION STRIP - glucose
- Electro-chemical technology for a more practical use.
- Requires very little blood samples (1 μl).
- Short time for the results (5 sec.)
The first and only multi-parameter device with double technology
REFLECTOMETRIC SUCTION STRIP - cholesterol and tryglicerides
- Multicare is a unique technology.
- It allows a more functional self-monitoring of triglycerides and cholesterol.
Biosensor
Reflectometric
• 23965 MULTICARE "IN" KIT - Italian manual
• 23966 MULTICARE "IN" KIT - English manual
• 23967 MULTICARE "IN" KIT - CD multilanguage manual
*
*
Includes 10 languages: GB, IT, FR, ES, GR, PT, PL, SL, HU, TR
A new approach for the periodical self-monitor of risk factors
- cholesterol, triglycerides and glucose. The only device on sale
with reflecto-metrical and electro-chemical bio sensor suction.
Multicare "IN" is supplied in carton box with a nylon bag, 10
glucose strips, lancet device, 10 lancets, rapid guide and user
manual. Multicare "IN" has 7 language box: Italian, English,
French, Spanish, Greek, Portuguese, Polish.
• 23982 SOFTWARE FOR MULTICARE "IN" - English, French,
Italian, Spanish
Operating system necessary to installation: Windows XP, Vista,
16 Mb Ram, 10 Mb remaining space on hard disk
Versatile
Blood sample can
be dropped both
on the inserted strip
and on the external
strip.
Innovative
Reduced blood
volume 3
microlitres of
blood are needed
for the glucose test.
Practical
Device activation
by inserting
the strip or by
pushing the button
7 Languages box:
English, Italian, French, Spanish, Greek, Polish,
Portuguese.
• 23948 MULTICARE KIT - English/Spanish, manual
• 23950 MULTICARE KIT + 10 glucose strips - English/Italian manual
Unique diagnostic device for self-check of glucose, cholesterol and triglycerides.
Multi-parameter technology allows to measure, with the same
reflectometer, different parameters by simply changing type of strips: a
chip in each pack of strips is specific for each analysis. Regular measuring of
these three parameters is important to
prevent cardiovascular pathologies
if we consider that intolerance to glucose, hyper-cholesterolemia and
hyper-triglyceridemia are three of the main cardiovascular risk factors,
along with age, obesity, lifestyle, smoking and arterial hypertension.
Multicare is supplied in 3 language carton box (English, Italian, Spanish)
with a nylon bag, lancet device, 10 lancets, user manual (English, Italian,
Spanish as above). Available on request French and Portuguese manual.
• 32212 LITHIUM BATTERY CR2032
1...,5,6,7,8,9,10,11,12,13,14 16,17,18,19,20,21,22,23,24,25,...332