Gima International Catalogue 2014-2015 - page 316

STERILIZATION
307
As regards to safety in health practice, sterilisation is the first
aspect to consider. Autoclaves offer physical and legal safety.
This is why autoclaves must be chosen according to rational
logics and based on professional and not only cost-related
evaluations.
With the new EN 13060 standard, the choice of the right
autoclave is now easier for professionals: they must choose a
certified, adequate model, based on the type of materials to
sterilise. A B-type loads autoclave allows to sterilize hollow ma-
terials such as handpieces and turbines and porous materials
(overalls, gauze...).
P.I.D. System (Proportional Integral Derivate)
It represents the top of closed loop controls. P.I.D. ensures a
constant control and monitoring of the whole operating sy-
stem of the autoclave, acting automatically in case of anoma-
lies or incorrect technical and electronic parameters.
Internal tanks
All the autoclaves are equipped with an internal tank for pure
water and another for used water. Each tank is equipped with
probes to detect the minimum and maximum water levels.
Preset temperatures
The preset temperatures used in our autoclaves cycles are
134°C and 121°C. 134°C cycles are normally used for steriliza-
tion of solid and ferrous materials. 121°C cycles are normally
used for sterilization of thermoplastic and delicate materials.
Ease of use
Sterilization cycle is selected by pushing one button and activa-
ted by pushing another. First button allows to scroll and view
data about all sterilization cycles on the display and select the
cycle that suits your materials best, second button automatical-
ly starts the whole sterilization cycle. It is impossible to make
mistake or choose an inadequate sterilization cycle. In case of
any error or warning a series of messages and LEDS will inform
you about the problem.
Fully automatic cycles
All cycles are fully automatic, with all steps managed by the
leading-edge computer board with a powerful microprocessor.
Each step (vacuum, preheating, exposure time, drying) is au-
tomatically monitored, assisted and handled. There is no need
for human intervention in cycle management.
Cycles without operator intervention and with autoshutdown
In sterilization cycles an automatic function will trigger an
anti-condensation process and auto-shutdown if the operator
is not by the machine when the cycle ends.
Test cycles
Our autoclaves are equipped with test cycles for periodic con-
trol by means of physical and functional tests.
Helix test, to assess vacuum capacity in hollow bodies.
Bowie & Dick test to evaluate vacuum capability in hollow bo-
dies. Vacuum test to evaluate vacuum retaining capability.
Costantly monitored cycles
A device constantly controls and monitors the sterilization cycles.
Any anomaly or uncommon feature is quickly detected and
immediately blocked if it jeopardises the sterilization cycles.
The operator is warned of the anomaly by a message.
All cycles ensure sterilization of B-type loads
All the sterilization cycles feature the fractional vacuum system
as well as the controls of parameters that ensure sterilization
of B-type loads. Therefore, even if the type of cycle chosen is
incorrect the sterilization carried out on the material will be
equally adequate.
EUROPA EVO AND ALIA: CLASS B AUTOCLAVES 15
AND
24 l
TECHNICAL SPECIFICATIONS
35675
35653
35676
35657
Alia B - 15 l
Europa B - 15 l Alia B - 24 l
Europa B - 24 l
External size mm (WxHxD):
510x400x640
510x390x590
510x400x730
510x390x730
Chamber size mm (Øxdept):
245x320
245x320
245x500
245x500
Operating voltage
230V - 50/60 Hz
230V - 50/60 Hz 230V - 50/60 Hz 230V - 50/60 Hz
Max absorbed power
1700 W
1700 W
2000 W
2000 W
Weight kg:
57
54
61
58
Vocal directions:
yes
no
yes
no
Printer presetting for traceability labels:
yes
no
yes
no
Built in printer:
no
yes
no
yes
Sd card:
yes
no
yes
no
Biological incubator connector:
yes
yes
yes
yes
Manual closing:
yes
yes
yes
yes
Fitting for pura deioniser:
yes
yes
yes
yes
PID system
yes
yes
yes
yes
0434
CHAMBER TEST
Constant control and
monitoring of the entire
autoclave functional system.
Collection and registration
of data related to cycles and
monitoring of the autoclave are
carried out through SD card.
(Alia B only).
Sterilization Cycles
121°C-134°C suitable for both
enveloped and free materials.
All cycles are for type-B loads.
cicli
flash
flash
cycle
Cycles
Wrapped 121° C
Flash 134° C
Wrapped 134° C
Prion 134° C
Alia B 15
60 min.
32 min.
47 min.
62 min.
Europa B EVO
60 min.
32 min.
47 min.
62 min.
Alia B 24
56 min.
32 min.
43 min.
58 min.
Europa B EVO24
56 min.
32 min.
43 min.
58 min.
Average time of the total cycle*
* Times expressed in minutes. The total time includes: vacuum, pre-heating time, cycle
and drying phase. The times are to be intended for a fully loaded autoclave.
Autoclave equipped
with integrated printer
35657
35653
GIMA
code
CLASS B AUTOCLAVES
35653
Europa B Evo Autoclave - 15 l
35657
Europa B Evo Autoclave - 24 l
33250
Thermal paper 57mm x 25m (pack of 5 rolls)
35675
Alia B Autoclave -15 l
35676
Alia B Autoclave - 24 l
BACTERIAL FILTER conical threading 1/8
35672
Bacterial filter for Europa B and Alia B
Compatible also withW&H, Cominox, Mocom, Mediline, Euronda